CANx devices
🔗 CANx protocol introduction
LogicMachine is required for commissioning and inter-connectivity with other protocols
- CANx 8 x 0-10V Analog outputs
- CANx DALI gateway
- CANx 8 x PT1000 sensor inputs
- CANx 10A Relays
- CANx 6 x 16A Relays, high switch-on current
- CANx Shutter actuator
- CANx 8 x Analog inputs / Digital outputs
- CANx 16 x Analog inputs / Digital outputs
- CANx 10 x Push-button inputs, 1 x PT1000 sensor input
- CANx active line filter / line termination device
- CANx inline repeater
CAN-AO8
CAN-AO8-LoRa
CANx 8 x 0-10V Analog outputs

DIN-rail mounted module with eight independent 0–10V analog outputs, ideal for controlling dimmable lighting, HVAC systems, or analog-driven devices within a CANx automation network.
Physical interfaces:
- Analog outputs x 8 (0-10V)
- CAN FT x 1
- Programming / Reset button x 1
- USB 2.0 x 1 (only for device firmware upgrade)
- DIN module width: 3
Radio interface (CAN-AO8-LoRA only):
- LoRa 433 x 1
- Transmitter power: 1.6 .. 50 mW (configurable)
- Frequency range: 433 .. 434.75 MHz
CAN-DALI-M3
CAN-DALI-LoRa
CANx DALI gateway


DIN-rail mounted module with eight independent 0–10V analog outputs, ideal for controlling dimmable lighting, HVAC systems, or analog-driven devices within a CANx automation network.
LogicMachine5 is required for operation
Physical interfaces:
- DALI bus
- DALI power supply converter (15 V .. 18 V DC)
- CAN FT x 1
- Programming / Reset button x 1
- USB 2.0 x 1 (only for device firmware upgrade)
- DIN module width: 3
Radio interface (CAN-DALI-LoRA only):
- LoRa 433 x 1
- Transmitter power: 1.6 .. 50 mW (configurable)
- Frequency range: 433 .. 434.75 MHz
CAN-PT8
CAN-PT8-LoRa
CANx 8 x PT1000 sensor inputs


DIN-rail mounted module featuring eight PT1000 sensor inputs, ideal for precise temperature monitoring in heating and industrial automation systems.
Physical interfaces:
- PT1000 sensor input x 8
- CAN FT x 1
- Programming / Reset button x 1
- USB 2.0 x 1 (only for device firmware upgrade)
- DIN module width: 3
Radio interface (CAN-PT8-LoRA only):
- LoRa 433 x 1
- Transmitter power: 1.6 .. 50 mW (configurable)
- Frequency range: 433 .. 434.75 MHz
CAN-R4, CAN-R6, CAN-R8
CAN-R4-LoRa, CAN-R6-LoRa
CANx 4 / 6 / 8 x 10 A Relays


DIN-rail mounted 4/6/8-channel relay module designed for switching of AC/DC loads.
Physical interfaces:
- Relays x 4 (CAN-R4), x 6 (CAN-R6) or x 8 (CAN-R8)
- Relay current: 10 A @ 230V AC; 5 A @ 30V DC
- Relay control buttons x 4 (CAN-R4), x 6 (CAN-R6) or x 8 (CAN-R8)
- CAN FT x 1
- Programming / Reset button x 1
- USB 2.0 x 1 (only for device firmware upgrade)
- DIN module width: 4
Radio interface (CAN-R4-LoRA and CAN-R6-LoRA only):
- LoRa 433 x 1
- Transmitter power: 1.6 .. 50 mW (configurable)
- Frequency range: 433 .. 434.75 MHz
CAN-R4 datasheet
CAN-R6 datasheet
CAN-R8 datasheet
CAN-R4-LoRa datasheet
CAN-R6-LoRa datasheet
CAN-R6HC
CAN-R6HC-LoRa
CANx 6 x 16 A Relays, high starting current


CAN-R6HC is a DIN-rail mounted 6-channel relay module designed for switching of AC/DC loads with a high starting (inrush) current.
Physical interfaces:
- Relays x 6
- Relay current: 16 A
- Inrush current: 165 A / 20 ms; 492A / 1.5ms (LED)
- CAN FT x 1
- Programming / Reset button x 1
- USB 2.0 x 1 (only for device firmware upgrade)
- DIN module width: 6
Radio interface (CAN-R6HC-LoRA only):
- LoRa 433 x 1
- Transmitter power: 1.6 .. 50 mW (configurable)
- Frequency range: 433 .. 434.75 MHz
CAN-SA2
CANx 2 x Shutter actuator channels + 4 x Push-button inputs

CAN-SA2 is a DIN-rail mounted 2-channel shutter actuator designed for precise control of shutters, blinds, curtains, and other motorized shading devices.
Physical interfaces:
- Relays 2 x 2
- Relay current: 5 A
- Relay control buttons x 4
- digital inputs for push-buttons x 4
- CAN FT x 1
- Programming / Reset button x 1
- USB 2.0 x 1 (only for device firmware upgrade)
- DIN module width: 4
CAN-UIO8
CAN-UIO8-LoRa
CANx 8 x Analog inputs / Digital outputs


CAN-UIO8 is a DIN-rail mounted universal I/O module featuring 8 configurable analog inputs or digital outputs, designed for versatile signal control in building automation systems.
Physical interfaces:
- Analog input / Digital output x 8 (Inputs: 0-30 V / Outputs: 24 V)
- CAN FT x 1
- Programming / Reset button x 1
- USB 2.0 x 1 (only for device firmware upgrade)
- DIN module width: 3
Radio interface (CAN-UIO8-LoRA only):
- LoRa 433 x 1
- Transmitter power: 1.6 .. 50 mW (configurable)
- Frequency range: 433 .. 434.75 MHz
CAN-UIO16
CANx 16 x Analog inputs / Digital outputs

CAN-UIO16 is a DIN-rail mounted universal I/O module featuring 16 configurable analog inputs or digital outputs, designed for versatile signal control in building automation systems.
Physical interfaces:
- Analog input / Digital output x 16 (Inputs: 0-30 V / Outputs: 24 V)
- CAN FT x 1
- Programming / Reset button x 1
- USB 2.0 x 1 (only for device firmware upgrade)
- DIN module width: 3
CAN-UI10
CANx 10 x Push-button inputs / 1 x PT1000 sensor input, flush-mounted

CAN-UI10 is a flush-mounted 10-channel binary input and LED controller with a built-in temperature sensor and thermostat, transforming any conventional switch into a CANx sensor.
Physical interfaces:
- Binary input / LED control ports x 10 (Outputs: 5 V, 5 mA)
- PT1000 sensor input x 1
- On-board temperature sensor
- CAN FT x 1
- Programming / Reset button x 1
- USB 2.0 x 1 (only for device firmware upgrade)
CANT
CANx line termination device

CANT is a flush-mounted line termination device designed to optimize signal integrity on extended CANx lines with a small number of connected devices. Line termination strength is adjustable via on-board DIP switch.
Physical interfaces:
- DIP switch x 1
- CAN FT x 1
CAN-CANLF
CANx In-line repeater

CAN-CANLF is a flush-mounted in-line repeater designed to extend CANx lines by supporting up to 32 additional devices.
Physical interfaces:
- CAN FT x 2
- Status LED x 2