🔗 CANx protocol introduction

LogicMachine is required for commissioning and inter-connectivity with other protocols



CAN-AO8

CAN-AO8-LoRa

CANx 8 x 0-10V Analog outputs

DIN-rail mounted module with eight independent 0–10V analog outputs, ideal for controlling dimmable lighting, HVAC systems, or analog-driven devices within a CANx automation network.

Physical interfaces:

  • Analog outputs x 8 (0-10V)
  • CAN FT x 1
  • Programming / Reset button x 1
  • USB 2.0 x 1 (only for device firmware upgrade)
  • DIN module width: 3

Radio interface (CAN-AO8-LoRA only):

  • LoRa 433 x 1
  • Transmitter power: 1.6 .. 50 mW (configurable)
  • Frequency range: 433 .. 434.75 MHz

CAN-AO8 datasheet
CAN-AO8-LoRa datasheet

CAN-DALI-M3

CAN-DALI-LoRa

CANx DALI gateway


DIN-rail mounted module with eight independent 0–10V analog outputs, ideal for controlling dimmable lighting, HVAC systems, or analog-driven devices within a CANx automation network.
LogicMachine5 is required for operation

Physical interfaces:

  • DALI bus
  • DALI power supply converter (15 V .. 18 V DC)
  • CAN FT x 1
  • Programming / Reset button x 1
  • USB 2.0 x 1 (only for device firmware upgrade)
  • DIN module width: 3

Radio interface (CAN-DALI-LoRA only):

  • LoRa 433 x 1
  • Transmitter power: 1.6 .. 50 mW (configurable)
  • Frequency range: 433 .. 434.75 MHz

CAN-DALI-M3 datasheet
CAN-DALI-LoRa datasheet

CAN-PT8

CAN-PT8-LoRa

CANx 8 x PT1000 sensor inputs


DIN-rail mounted module featuring eight PT1000 sensor inputs, ideal for precise temperature monitoring in heating and industrial automation systems.

Physical interfaces:

  • PT1000 sensor input x 8
  • CAN FT x 1
  • Programming / Reset button x 1
  • USB 2.0 x 1 (only for device firmware upgrade)
  • DIN module width: 3

Radio interface (CAN-PT8-LoRA only):

  • LoRa 433 x 1
  • Transmitter power: 1.6 .. 50 mW (configurable)
  • Frequency range: 433 .. 434.75 MHz

CAN-PT8 datasheet
CAN-PT8-LoRa datasheet

CAN-R4, CAN-R6, CAN-R8

CAN-R4-LoRa, CAN-R6-LoRa

CANx 4 / 6 / 8 x 10 A Relays


DIN-rail mounted 4/6/8-channel relay module designed for switching of AC/DC loads.

Physical interfaces:

  • Relays x 4 (CAN-R4), x 6 (CAN-R6) or x 8 (CAN-R8)
  • Relay current: 10 A @ 230V AC; 5 A @ 30V DC
  • Relay control buttons x 4 (CAN-R4), x 6 (CAN-R6) or x 8 (CAN-R8)
  • CAN FT x 1
  • Programming / Reset button x 1
  • USB 2.0 x 1 (only for device firmware upgrade)
  • DIN module width: 4

Radio interface (CAN-R4-LoRA and CAN-R6-LoRA only):

  • LoRa 433 x 1
  • Transmitter power: 1.6 .. 50 mW (configurable)
  • Frequency range: 433 .. 434.75 MHz

CAN-R4 datasheet
CAN-R6 datasheet
CAN-R8 datasheet
CAN-R4-LoRa datasheet
CAN-R6-LoRa datasheet

CAN-R6HC

CAN-R6HC-LoRa

CANx 6 x 16 A Relays, high starting current


CAN-R6HC is a DIN-rail mounted 6-channel relay module designed for switching of AC/DC loads with a high starting (inrush) current.

Physical interfaces:

  • Relays x 6
  • Relay current: 16 A
  • Inrush current: 165 A / 20 ms; 492A / 1.5ms (LED)
  • CAN FT x 1
  • Programming / Reset button x 1
  • USB 2.0 x 1 (only for device firmware upgrade)
  • DIN module width: 6

Radio interface (CAN-R6HC-LoRA only):

  • LoRa 433 x 1
  • Transmitter power: 1.6 .. 50 mW (configurable)
  • Frequency range: 433 .. 434.75 MHz

CAN-R6HC datasheet
CAN-R6HC-LoRa datasheet

CAN-SA2

CANx 2 x Shutter actuator channels + 4 x Push-button inputs

CAN-SA2 is a DIN-rail mounted 2-channel shutter actuator designed for precise control of shutters, blinds, curtains, and other motorized shading devices.

Physical interfaces:

  • Relays 2 x 2
  • Relay current: 5 A
  • Relay control buttons x 4
  • digital inputs for push-buttons x 4
  • CAN FT x 1
  • Programming / Reset button x 1
  • USB 2.0 x 1 (only for device firmware upgrade)
  • DIN module width: 4

CAN-SA2 datasheet

CAN-UIO8

CAN-UIO8-LoRa

CANx 8 x Analog inputs / Digital outputs


CAN-UIO8 is a DIN-rail mounted universal I/O module featuring 8 configurable analog inputs or digital outputs, designed for versatile signal control in building automation systems.

Physical interfaces:

  • Analog input / Digital output x 8 (Inputs: 0-30 V / Outputs: 24 V)
  • CAN FT x 1
  • Programming / Reset button x 1
  • USB 2.0 x 1 (only for device firmware upgrade)
  • DIN module width: 3

Radio interface (CAN-UIO8-LoRA only):

  • LoRa 433 x 1
  • Transmitter power: 1.6 .. 50 mW (configurable)
  • Frequency range: 433 .. 434.75 MHz

CAN-UIO8 datasheet
CAN-UIO8-LoRa datasheet

CAN-UIO16

CANx 16 x Analog inputs / Digital outputs

CAN-UIO16 is a DIN-rail mounted universal I/O module featuring 16 configurable analog inputs or digital outputs, designed for versatile signal control in building automation systems.

Physical interfaces:

  • Analog input / Digital output x 16 (Inputs: 0-30 V / Outputs: 24 V)
  • CAN FT x 1
  • Programming / Reset button x 1
  • USB 2.0 x 1 (only for device firmware upgrade)
  • DIN module width: 3

CAN-UIO16 datasheet

CAN-UI10

CANx 10 x Push-button inputs / 1 x PT1000 sensor input, flush-mounted

CAN-UI10 is a flush-mounted 10-channel binary input and LED controller with a built-in temperature sensor and thermostat, transforming any conventional switch into a CANx sensor.

Physical interfaces:

  • Binary input / LED control ports x 10 (Outputs: 5 V, 5 mA)
  • PT1000 sensor input x 1
  • On-board temperature sensor
  • CAN FT x 1
  • Programming / Reset button x 1
  • USB 2.0 x 1 (only for device firmware upgrade)

CAN-UI10 datasheet

CANT

CANx line termination device

CANT is a flush-mounted line termination device designed to optimize signal integrity on extended CANx lines with a small number of connected devices. Line termination strength is adjustable via on-board DIP switch.

Physical interfaces:

  • DIP switch x 1
  • CAN FT x 1

CANT datasheet

CAN-CANLF

CANx In-line repeater

CAN-CANLF is a flush-mounted in-line repeater designed to extend CANx lines by supporting up to 32 additional devices.

Physical interfaces:

  • CAN FT x 2
  • Status LED x 2

CAN-CANLF datasheet